Cummins Marine Emergency 720KW diesel generator set, powered by Cummins engine with Stamford Alternator, Brushless, Self-excited, for marine Emergency power supply.
Power | 720kw/900kva |
---|---|
Frequency/voltage | 50hz, 400v, 3Phase, 60HZ available |
Engine | KTA38-DM |
Alternator | Leroy-Somer, Marathon, Stamford |
Displacement | 38L |
Cooling method | Radiator & Fan |
Marine Class | CC/IMO |
Starting Method | electric start/Auto start |
Cummins KTA38-DM Marine Emergency 720KW diesel generator set, used for all kind of ships/vessels/boats/offshore/platform emergency or main electric power supply, cooling by radiator. The following are optional configurations:
power kw/kva | Engine | Cooling Method | Marine Class |
---|---|---|---|
30/37.5 | 4BTA3.9-GM47 | Heat exchanger | CCS |
40/50 | 4BTA3.9-GM47 | Heat exchanger | CCS |
50/62.5 | 6BT5.9-GM83 | Heat exchanger | CCS |
64/80 | 6BT5.9-GM83 | Heat exchanger | CCS |
75/93.8 | 6BT5.9-GM83 | Heat exchange | CCS |
90/112.5 | 6BTA5.9-GM100 | Heat exchanger | CCS |
100/125 | 6CT8.3-GM115 | Heat exchanger | CCS |
120/150 | 6CTA8.3-GM155 | Heat exchanger | CCS/IMO2 |
150/187.5 | 6LTAA8.9-GM200 | Heat exchanger | CCS/IMO2 |
180/225 | 6LTAA8.9-GM200 | Heat exchanger | CCS/IMO2 |
200/250 | NTA855-DM, N855-DM | Heat exchanger | CCS/IMO/IMO2 |
250/312.5 | NTA855-DM, N855-DM | Heat exchanger | CCS/IMO/IMO2 |
280/350 | NTA855-DM, N855-DM | Heat exchanger | CCS/IMO/IMO2 |
300/375 | KTA19-DM, K19-DM | Heat exchanger | CCS/IMO/IMO2 |
350/437.5 | KTA19-DM, K19-DM | Heat exchanger | CCS/IMO/IMO2 |
400/500 | KTA19-DM, K19-DM | Heat exchanger | CCS/IMO/IMO2 |
500/625 | KT38-DM, K38-DM | Heat exchanger | CCS/IMO/IMO2 |
600/750 | KTA38-DM | Heat exchanger | CCS/IMO |
650/812.5 | K38-DM | Heat exchanger | CCS/IMO2 |
700/875 | KTA38-DM, K38-DM | Heat exchanger | CCS/IMO/IMO2 |
800/1000 | KTA38-DM, K38-DM | Heat exchanger | CCS/IMO/IMO2 |
900/1125 | K50-DM | Heat exchanger | CCS/IMO2 |
1000/1250 | K50-DM | Heat exchanger | CCS/IMO2 |
Power kw/kva | Engine | Cooling method | Marine Class |
---|---|---|---|
40/50 | 4BTA3.9-GM47 | Radiator & Fan | CCS |
64/80 | 6BT5.9-GM83 | Radiator & Fan | CCS |
75/93.8 | 6BTAA5.9-GM115 | Radiator & Fan | CCS |
90/112.5 | 6BTAA5.9-GM115 | Radiator & Fan | CCS |
100/125 | 6BTAA5.9-GM115, 6CT8.3-GM115 | Radiator & Fan | CCS |
120/150 | 6CTA8.3-GM155 | Radiator & Fan | CCS/IMO2 |
150/187.5 | 6LTAA8.9-GM200 | Radiator & Fan | CCS/IMO2 |
180/225 | 6LTAA8.9-GM200 | Radiator & Fan | CCS/IMO2 |
200/250 | NTA855-DM, N855-DM | Radiator & Fan | CCS/IMO/IMO2 |
250/312.5 | NTA855-DM, N855-DM | Radiator & Fan | CCS/IMO/IMO2 |
280/350 | NTA855-DM, N855-DM | Radiator & Fan | CCS/IMO/IMO2 |
300/375 | KTA19-DM, K19-DM | Radiator & Fan | CCS/IMO/IMO2 |
350/437.5 | KTA19-DM, K19-DM | Radiator & Fan | CCS/IMO/IMO2 |
400/500 | KTA19-DM, K19-DM | Radiator & Fan | CCS/IMO/IMO2 |
500/625 | KT38-DM | Radiator & Fan | CCS/IMO |
600/750 | KTA38-DM | Radiator & Fan | CCS/IMO |
650/813 | K38-DM | Radiator & Fan | CCS/IMO2 |
700/875 | K38-DM | Radiator & Fan | CCS/IMO2 |
720/900 | KTA38-DM | Radiator & Fan | CCS/IMO |
800/1000 | KTA38-DM, K38-DM | Radiator & Fan | CCS/IMO/IMO2 |
900/1125 | K50-DM | Radiator & Fan | CCS/IMO2 |
1000/1250 | K50-DM | Radiator & Fan | CCS/IMO2 |