Cummins Marine Emergency 500KW diesel generator set, powered by Cummins engine with Stamford Alternator, Brushless, Self-excited, for marine Emergency power supply.
Power | 500kw/625kva |
---|---|
Frequency/voltage | 50hz, 400v, 3Phase, 60HZ available |
Engine | KT38-DM |
Alternator | Leroy-Somer, Marathon, Stamford |
Displacement | 38L |
Cooling method | Radiator & Fan |
Marine Class | CC/IMO |
Starting Method | electric start/Auto start |
Cummins KT38-DM Marine Emergency 500KW diesel generator set, used for all kind of ships/vessels/boats/offshore/platform emergency or main electric power supply, cooling by radiator. The following are optional configurations:
power kw/kva | Engine | Cooling Method | Marine Class |
---|---|---|---|
30/37.5 | 4BTA3.9-GM47 | Heat exchanger | CCS |
40/50 | 4BTA3.9-GM47 | Heat exchanger | CCS |
50/62.5 | 6BT5.9-GM83 | Heat exchanger | CCS |
64/80 | 6BT5.9-GM83 | Heat exchanger | CCS |
75/93.8 | 6BT5.9-GM83 | Heat exchange | CCS |
90/112.5 | 6BTA5.9-GM100 | Heat exchanger | CCS |
100/125 | 6CT8.3-GM115 | Heat exchanger | CCS |
120/150 | 6CTA8.3-GM155 | Heat exchanger | CCS/IMO2 |
150/187.5 | 6LTAA8.9-GM200 | Heat exchanger | CCS/IMO2 |
180/225 | 6LTAA8.9-GM200 | Heat exchanger | CCS/IMO2 |
200/250 | NTA855-DM, N855-DM | Heat exchanger | CCS/IMO/IMO2 |
250/312.5 | NTA855-DM, N855-DM | Heat exchanger | CCS/IMO/IMO2 |
280/350 | NTA855-DM, N855-DM | Heat exchanger | CCS/IMO/IMO2 |
300/375 | KTA19-DM, K19-DM | Heat exchanger | CCS/IMO/IMO2 |
350/437.5 | KTA19-DM, K19-DM | Heat exchanger | CCS/IMO/IMO2 |
400/500 | KTA19-DM, K19-DM | Heat exchanger | CCS/IMO/IMO2 |
500/625 | KT38-DM, K38-DM | Heat exchanger | CCS/IMO/IMO2 |
600/750 | KTA38-DM | Heat exchanger | CCS/IMO |
650/812.5 | K38-DM | Heat exchanger | CCS/IMO2 |
700/875 | KTA38-DM, K38-DM | Heat exchanger | CCS/IMO/IMO2 |
800/1000 | KTA38-DM, K38-DM | Heat exchanger | CCS/IMO/IMO2 |
900/1125 | K50-DM | Heat exchanger | CCS/IMO2 |
1000/1250 | K50-DM | Heat exchanger | CCS/IMO2 |
Power kw/kva | Engine | Cooling method | Marine Class |
---|---|---|---|
40/50 | 4BTA3.9-GM47 | Radiator & Fan | CCS |
64/80 | 6BT5.9-GM83 | Radiator & Fan | CCS |
75/93.8 | 6BTAA5.9-GM115 | Radiator & Fan | CCS |
90/112.5 | 6BTAA5.9-GM115 | Radiator & Fan | CCS |
100/125 | 6BTAA5.9-GM115, 6CT8.3-GM115 | Radiator & Fan | CCS |
120/150 | 6CTA8.3-GM155 | Radiator & Fan | CCS/IMO2 |
150/187.5 | 6LTAA8.9-GM200 | Radiator & Fan | CCS/IMO2 |
180/225 | 6LTAA8.9-GM200 | Radiator & Fan | CCS/IMO2 |
200/250 | NTA855-DM, N855-DM | Radiator & Fan | CCS/IMO/IMO2 |
250/312.5 | NTA855-DM, N855-DM | Radiator & Fan | CCS/IMO/IMO2 |
280/350 | NTA855-DM, N855-DM | Radiator & Fan | CCS/IMO/IMO2 |
300/375 | KTA19-DM, K19-DM | Radiator & Fan | CCS/IMO/IMO2 |
350/437.5 | KTA19-DM, K19-DM | Radiator & Fan | CCS/IMO/IMO2 |
400/500 | KTA19-DM, K19-DM | Radiator & Fan | CCS/IMO/IMO2 |
500/625 | KT38-DM | Radiator & Fan | CCS/IMO |
600/750 | KTA38-DM | Radiator & Fan | CCS/IMO |
650/813 | K38-DM | Radiator & Fan | CCS/IMO2 |
700/875 | K38-DM | Radiator & Fan | CCS/IMO2 |
720/900 | KTA38-DM | Radiator & Fan | CCS/IMO |
800/1000 | KTA38-DM, K38-DM | Radiator & Fan | CCS/IMO/IMO2 |
900/1125 | K50-DM | Radiator & Fan | CCS/IMO2 |
1000/1250 | K50-DM | Radiator & Fan | CCS/IMO2 |
Copyright Master Power | All Rights Reserved
Fill in your details and we’ll get back to you as soon as possible.
Successfully!
The form was sent successfully! We will reply you as soon as possible.
Please pay attention to the email with the suffix “@mastpower.com”.
Fill in your details and we’ll get back to you as soon as possible.